Phocos CX20-48V Solar Charge Controller (24/48V)
Description
<
LAST UNITS of 48Vdc CONTROLLER
Phocos CX20-48V Solar Charge Controller for 24/48V solar systems
PV solar charge controller
The Phocos CX48 Series offers outstanding features for its class: along with a PWM charge controller with integrated temperature compensation, the CX controller comes equipped with an extensive range of control, programming and safety functions. The battery charge status is continuously displayed via a bar graph, including the input and output current of the battery as well as the load status (e.g. overloading, load short circuiting). The deep discharge protection mode has 5 settings: two fixed voltages, two charging states or adaptive (for battery protection). An audible alarm and a programmable nightlight function are standard on all CX controllers.
- LCD - Charge and discharge status display
- Audible alert before load disconnect
- Load status indication
- Choose between 5 load disconnect algorithms
- Four-stage PWM charging (series type)
- Integrated temperature compensation
- Full electronic protection
Example of PV off-grid diagrams
Downloads
Phocos CX48 - Datasheet
Phocos CX48 - User Manual
Phocos CX48 - CE Certificate
CXCOM software
CXCOM configuration software for CX-controllers, quick and easy view and configuration of individual load-time, system components and data-logger.
Technical Data
Product | Phocos CX48 20A | 40A |
Type | Charge Controller 24/48V |
System | Photovoltaic Systems |
Function | Overcharge Protection and Deep Discharge Protection |
Batteries | GEL, AGM, Lead-Acid, Flooded |
Charging Mode | PWM |
Nominal Voltage | 24/48V automatic detection |
Max. charge/load current | 20A | 40A |
Float charge | 27.4/54.8V (25°C) |
Main charge | 28.8/57.6V (25°C), 30min. (daily) |
Boost charge | 28.8/57.6V (25°C), 2h activation: battery voltage < 24.6/49.2V |
Equalization | 29.6/59.2V (25°C), 2h activation: battery voltage <24.2/48.4V |
Max. panel voltage | 50V in 24V system | 95V in 48V sysem |
Deep discharge protection | State of charge dependent A: 22.8-23.8V/45.6-47.6V | B: 22.0-23.5V/44.0-47.0V | Voltage dependent A: 22/44V | B: 23/46V | Adaptive 22.0-24.4V/44.0-48.8V | Reconnect level 25.6/51.2V |
Overvoltage protection | 31.0/62.0V |
Undervoltage protection | 21.0/42V |
Temperature compensation | -50 mV/K at 24V | -100 mV/K at 48V |
Self consumption | < 10mA |
Grounding | positive grounding |
Ambient temperature | −20 to +50°C |
Max. height | 4.000m above sea level |
Wire cross section | =< 16 mm2 |
Weight | 348g | 365g |
Dimensions (WxHxD) | 110x92x58 mm |
Protection class | IP22 |
Warranty | 2 years |