PVshop.eu | EBORX Sp. z o.o. Authorized Phocos DistributorSizing the charge controllers in PV off-grid systems (general rules):
Diagrams Guide PV Off-Grid Systems
System Voltage: 12VCharge current: 4AMax. Input Voltage: 30VMax. Input Power: 70WGrounding: positiveCharging method: PWM
Availability: require pre order (waiting time ~4-6 weeks)
Limitations: max 3 units per order
System Voltage: 12/24VCharge current: 5AMax input voltage: 30/50VMax. Input Power: 90/180WLow voltage disconnect: yesGrounding: common positiveCharging method: PWM
Availability: on request
System Voltage: 12/24VCharge current: 10AMax. Input Voltage: 30/50VMax. Input Power: 175/350WLow voltage disconnect: yesGrounding: negativeCharging method: PWM
System Voltage: 12VCharge current: 10AMax. Input Voltage: 30VMax. Input Power: 175WGrounding: positiveCharging method: PWM
System Voltage: 12/24VCharge current: 10AMax input voltage: 30/50VLow voltage disconnect: yesGrounding: common positiveCharging method: PWM
System Voltage: 12/24VCharge current: 10AMax. Input Voltage: 30/50VLow voltage disconnect: yesGrounding: common negativeCharging method: PWM
System Voltage: 12/24VCharge current: 20AMax. Input Voltage: 30/50VMax. Input Power: 350/700WLow voltage disconnect: yesGrounding: negativeCharging method: PWM
System Voltage: 12/24VCharge current: 20AMax input voltage: 30/50VMax input power: 175/350WLow voltage disconnect: yesGrounding: positiveCharging method: PWM
Dual Battery Solar Charge Controller with LCDNominal voltage: 12/24V (autodetection)Max charge current: 20A (Isc)Panel max voltage: 30/50V (Voc) for 12/24V systemsCharging method: PWM 4-stageMonitoring: LC-DisplayFunction: deep-discharge protection of battery, data logger-2 years, external temperature sensor, negative pole grounded
System Voltage: 12/24VCharge current: 20AMax. Input Voltage: 30/50VMax. Input Power: 350/700WLow voltage disconnect: yesGrounding: common negativeCharging method: PWM
System Votage: 12/24VCharge current: 20AMax. Input Voltage: 30/50VMax. Input Power: 350/700WLow voltage disconnect: yesGrounding: negativeCharging method: PWM
System Voltage: 12/24VCharge current: 40AMax input voltage: 30/50VMax input power: 700/1050WLow voltage disconnect: yesGrounding: negativeCharging method: PWM
12/24V PV solar/battery systemsCharge current: 15AMax input voltage: 85VocMax input power: 250/500WLow voltage disconnect: yesGrounding: common negativeCharging method: MPPT
12/24V PV solar/battery systemsCharge current: 15AMax input voltage: 85VocMax input power: 250/500WLow voltage disconnect: yesGrounding: positiveCharging method: MPPT
System Voltage: 12/24VCharge current: 15AMax. Input Voltage: 85VocMax. Input Power: 250/500WLow voltage disconnect: yesGrounding: common negativeCharging method: MPPT
System Voltage: 12/24VCharge current: 30AMax. Input Voltage: 95VocMax. Input Power: 450/900WLow voltage disconnect: yesGrounding: common negativeCharging method: MPPT
Remote controller for individual settings and operationCompatible with all Phocos CIS controllersInfrared interface
Infrared to USB programming accessory for CIS series controllersEnables individual system settings and parametersCompatible with all Phocos CIS controllerEnables access to datalogger info (CIS-MPPT only)
Displays panel current, load current, and battery voltageLarge three-digit displayOne push buttonThree LEDs help indicate which value is displayed by LCDDIN rail adapter for wall mounting
Solar charge controller for 12/24V PV solar systemsNominal voltage: 12/24V (autodetection)Panel max current: 10A (Isc)Panel max voltage: 30/50V (Voc) in 12/24V systemsCharging method: PWM 3-stageMonitoring: three LEDFunction: protection against overcharge- and deep-discharge of battery
SALE OFF
Solar charge controller for 12/24V negative grounded systemsNominal voltage: 12/24V (autodetection)Panel max current: 20A (Isc)Panel max voltage: 30/50V (Voc) for 12/24V systemsCharging method: PWM 4-stageMonitoring: LCD-DisplayFunction: protection against overcharge- and deep-discharge of battery, datalogger (one year), negative grounding (N-series)
Solar charge controller for 12/24V negative grounded systemsNominal voltage: 12/24V (autodetection)Panel max current: 40A (Isc)Panel max voltage: 30/50V (Voc) for 12/24V systemsCharging method: PWM 4-stageMonitoring: LCD-DisplayFunction: protection against overcharge- and deep-discharge of battery, datalogger (one year), negative grounding (N-series)
Waterproof (IP68) PV solar charge controllerLoads: dual loads (not dimmable)Nominal voltage: 12/24V (autodetection)Panel max current: 10A (Isc)Panel max voltage: 42/52V (Voc) in 12/24V systemsCharging method: PWM 4-stageMonitoring: LED's, positive-grounding possible (on plus line)Function: protection against overcharge- and deep-discharge of battery, programmable for two loads (2L series)
Waterproof (IP68) PV solar charge controllerLoads: dual loads (not dimmable)Nominal voltage: 12/24V (autodetection)Panel max current: 20A (Isc)Panel max voltage: 42/52V (Voc) in 12/24V systemsCharging method: PWM 4-stageMonitoring: LED's, positive-grounding possible (on plus line)Function: protection against overcharge- and deep-discharge of battery, programmable for two loads (2L series)
Waterproof (IP68) PV solar charge controllerLoads: single load (dimmable)Nominal voltage: 12/24V (autodetection)Panel max current: 10A (Isc)Panel max voltage: 42/52V (Voc) in 12/24V systemsCharging method: PWM 4-stageMonitoring: LED's, positive-grounding possible (on plus line)Function: protection against overcharge- and deep-discharge of battery, programmable for one load
Waterproof (IP68) PV solar charge controllerLoads: single load (dimmable)Nominal voltage: 12/24V (autodetection)Panel max current: 20A (Isc)Panel max voltage: 42/52V (Voc) in 12/24V systemsCharging method: PWM 4-stageMonitoring: LED's, positive-grounding possible (on plus line)Function: protection against overcharge- and deep-discharge of battery, programmable for one load
Display for CA and CML3-digit LCD DisplayChoice of the displayed valuePrepared for DIN rail
Display for CXN series3-digit LCD DisplayChoice of the displayed valuePrepared for DIN rail (35mm)
Temperature sensor for CXNSimple assemblyWide temperature range
Nominal voltage: 24/48V (autodetection)Panel max current: 20A (Isc)Panel max voltage: 50/95V (Voc) in 24/48V systemsCharging method: PWM 4-stageMonitoring: LCD-DisplayFunction: protection against overcharge- and deep-discharge of battery, datalogger (one year)
Select all
Necessary for the website to function
Functional
Analytical
Analytical software provider
Marketing